NATO EPVAT testing

Left to right: 7.62 mm NATO, 5.56 mm NATO and 9 mm NATO ammunition.

NATO EPVAT testing is one of the three recognized classes of procedures used in the world to control the safety and quality of firearms ammunition.

Beside this, there are also the Commission Internationale Permanente pour l'Epreuve des Armes à Feu Portatives (C.I.P.) class of procedures and the Sporting Arms and Ammunition Manufacturers' Institute (SAAMI) class of procedures.

EPVAT Testing is described in unclassified documents by NATO, more precisely by the AC/225 Army Armaments Group (NAAG).[1]

EPVAT is an abbreviation for "Electronic Pressure Velocity and Action Time". With Action Time the (short amount of) time required between the ignition of the primer and the projectile leaving the barrel is meant. This is a comprehensive procedure for testing ammunition using state-of-the-art instruments and computers. The procedure itself is described in NATO document AC/225 (Com. III/SC.1)D/200.

Unlike the C.I.P. procedures aiming only at the user's safety, the NATO procedures for ammunition testing also includes comprehensive functional quality testing in relation with the intended use. That is, not only the soldier's safety is looked at, but also his capacity to incapacitate the enemy. As a result, for every ammunition order by NATO, a complete acceptance approval on both safety and functionality is performed by both NATO and the relevant ammunition manufacturers in a contradictory fashion.

For this, a highly accurate and indisputable protocol has been defined by NATO experts using a system of reference cartridges.[1][2][3]

The civilian organisations C.I.P. and SAAMI use less comprehensive test procedures than NATO, but NATO test centres have the advantage that only a few chamberings are in military use. The C.I.P. and SAAMI proof houses must be capable of testing hundreds of different chamberings requiring lots of different test barrels, etc..

NATO Reference cartridges system

In this system, the ammunition manufacturers, in close cooperation with NATO, have set aside a batch (also termed "lot") of ammunition they consider to be of very good quality and representative of ammunition that should be delivered to the armies in the next following years. This batch is maintained at approved NATO test centres and distributed to the manufacturers involved. When a new batch (lot) is delivered, a set of 20 reference cartridges are fired to see how they behave with the local equipment and with the current atmospheric conditions. Results are then compared to the reference values as maintained by the NATO and correctors (delta values) are computed. Then, the current batch (lot) of ammunition is fired and the correctors are applied on the measured value giving a result "comparable" to the reference itself.

This test is performed under normal conditions but also by simulating cold polar −54 °C (−65 °F) or hot desert 52 °C (126 °F) conditions using special cooling equipment and ovens to cool or heat the ammunition under test to the appropriate levels of humidity and temperatures required.[4][5]

Proofing

The minimum proof and performance requirements for small arms ammunition of NATO calibres are covered in STANAGs as follows:

  • 5.56 mm. STANAG 4172 and NATO Manual of Proof and Inspection AC/225 (LG/3-SG/1) D/8.
  • 7.62 mm. STANAG 2310 and NATO Manual of Proof and Inspection AC/225 (LG/3-SG/1) D/9.
  • 9 mm. STANAG 4090 and NATO Manual of Proof and Inspection AC/225 (P111-SP1) D/170(REV).
  • 12.7 mm. STANAG 4383 and NATO Manual of Proof and Inspection AC/225 (LG/3-SG/1) D/11.

Each weapon and component considered vulnerable to the effects of a rapid change in pressure, for example barrels, breech blocks and bolts, will be tested by firing one dry round at a corrected minimum of 25% over pressure and one oiled round at a corrected minimum of 25% over pressure. 25% over pressure means 25% in excess of the Service Pressure (Pmax). The Service Pressure is defined as the mean pressure generated by the Service Cartridge at a temperature of 21 °C (70 °F). Such a high pressure proof is conducted with both the weapon and ammunition conditioned to an ambient temperature of 21 °C (70 °F).

Each weapon will be individually tested, from an ammunition lot that produces a minimum corrected mean chamber pressure in accordance with the table below:[1]

Corrected Proof Pressure Requirement (Service Pressure (Pmax) + 25%)
Calibre Specific Weapon Detail Service Pressure Pmax
MPa / (psi)
Proof Round Pressure Requirement
MPa / (psi)
Detailed Requirement for Proof Ammunition
5.56 mm (5.56×45mm NATO) Designed to chamber NATO ammunition 430.0 / (62,366) 537.5 / (77,958) Pressure recorded in NATO design EPVAT Barrel with Kistler 6215 Transducer[6] or by equipment to Commission Internationale Permanente pour l’épreuve des Armes á Feu Portatives (C.I.P.) requirements
7.62 mm (7.62×51mm NATO) Designed to chamber NATO ammunition 415.0 / (60,190) 519.0 / (75,275) Pressure recorded in NATO design EPVAT Barrel with Kistler 6215 Transducer or by equipment to C.I.P. requirements
9 mm (9×19mm NATO) Designed to chamber NATO ammunition 252.0 / (36,550) 315.0 / (45,687) Pressure recorded in C.I.P. design barrel at mid case position
12.7 mm (12.7×99mm NATO) Designed to chamber NATO ammunition 417.0 / (60,481) 521.3 / (75,608) Pressure recorded in NATO design EPVAT Barrel with Kistler 6215 Transducer or by equipment to C.I.P. requirements
All other small arms ammunition for use in "non-NATO Chamber" weapons As defined by the current C.I.P. legislation. As defined by the current C.I.P. legislation.

The above proof round pressure requirements for the 9 mm and 12.7 mm rounds established by the British Ministry of Defence are higher than the current (2008) C.I.P. proof round pressure requirement legislation for the civilian equivalent 9mm Parabellum (C.I.P. Pmax rating 235 MPA / (34,083 psi) and .50 Browning (C.I.P. Pmax rating 370 MPA / (53,663 psi) rounds.[7] The 9x19mm NATO round can be regarded as overpressure ammunition

Unlike the civilian C.I.P. test procedures NATO EPVAT testing procedures for the "NATO chamberings" require the pressure sensor or transducer to be mounted ahead of the case mouth. The advantage of this mounting position is that there is no need to drill the cartridge case to mount the transducer. Drilling prior to firing is always a time consuming process (fast quality control and feedback to production is essential during the ammunition manufacturing process). The disadvantage of this mount is that the pressure rises much faster than in a drilled cartridge case. This causes high frequency oscillations of the pressure sensor (approx 200 kHz for a Kistler 6215 transducer) and this requires electronic filtering with the drawback that filtering also affects the lower harmonics where a peak is found causing a slight error in the measurement. This slight error is not always well mastered and this causes a lot of discussion about the filter order, cutoff frequency and its type (Bessel or Butterworth).[8]

Due to NATO EPVAT using technically differing proof test standards than SAAMI and C.I.P., EVPAT pressures cannot be directly compared with SAAMI and C.I.P. pressures.

Testing equipment providers

The following companies provide equipment to the NATO armies to perform this type of testing: (inexhaustive list)

  • Deby & Co, Ltd (Belgium)
  • DRELLO GmbH (Germany)
  • HPI (Austria)
  • Kistler Group
  • MS Instruments (England)
  • Prototypa (Czech Republic)
  • Sabre (England)
  • Stas (Italy)

See also

References

Notes
  1. ^ a b c Proof of Ordnance, Munitions, Armour and Explosives, Ministry of Defence Defence Standard 05-101 Part 1
  2. ^ Proof of Ordnance, Munitions, Armour and Explosives, Ministry of Defence Defence Standard 05-101 Part 2
  3. ^ Proof of Ordnance, Munitions, Armour and Explosives, Ministry of Defence Defence Standard 05-101 Part 3
  4. ^ Proof of Ordnance, Munitions, Armour and Explosives, Ministry of Defence Defence Standard 05-101 Part 3
  5. ^ NATO Small Arms Ammunition Interchangeability via Direct Evidence Testing
  6. ^ Defining Parameters for Ballistic High Pressure Sensors
  7. ^ C.I.P. decisions, texts and tables (free current C.I.P. CD-ROM version download (ZIP and RAR format))
  8. ^ Technical Report ARCCD-TR-95005 5.56 MM M856 TRACER MINI ROUND ROUND ROBIN STUDY, ARDEC/CCAC, October 1995 by Lascelles A. Geddes
Bibliography
  • Proof of Ordnance, Munitions, Armour and Explosives, Ministry of Defence Defence Standard 05-101 Part 1 – Requirements
  • Proof of Ordnance, Munitions, Armour and Explosives, Ministry of Defence Defence Standard 05-101 Part 2 – Guidance
  • Proof of Ordnance, Munitions, Armour and Explosives, Ministry of Defence Defence Standard 05-101 Part 3 – Statistical Methods for Proof
  • NATO Small Arms Ammunition Interchangeability via Direct Evidence Testing
  • C.I.P. decisions, texts and tables (free current C.I.P. CD-ROM version download (ZIP and RAR format))

External links

  • Army Armaments Group (NAAG)
  • Thales brochure on 5.56mm F1 ball ammunition conforming to the design parameters of the NATO STANAG 4172 and tested with Kistler 6215 transducers at different temperatures
  • THE ANALYSIS OF APPLICATION AND REQUIREMENTS SMALL CALIBER REFERENCE AMMUNITION AND POLISH ACHIEVEMENT IN THE FIELD OF WORKING OUT NATIONAL REFERENCE AMMUNITION
  • NATO Small Arms Ammunition Interchangeability via Direct Evidence Testing 25 May 2011
This article was sourced from Creative Commons Attribution-ShareAlike License; additional terms may apply. World Heritage Encyclopedia content is assembled from numerous content providers, Open Access Publishing, and in compliance with The Fair Access to Science and Technology Research Act (FASTR), Wikimedia Foundation, Inc., Public Library of Science, The Encyclopedia of Life, Open Book Publishers (OBP), PubMed, U.S. National Library of Medicine, National Center for Biotechnology Information, U.S. National Library of Medicine, National Institutes of Health (NIH), U.S. Department of Health & Human Services, and USA.gov, which sources content from all federal, state, local, tribal, and territorial government publication portals (.gov, .mil, .edu). Funding for USA.gov and content contributors is made possible from the U.S. Congress, E-Government Act of 2002.
 
Crowd sourced content that is contributed to World Heritage Encyclopedia is peer reviewed and edited by our editorial staff to ensure quality scholarly research articles.
 
By using this site, you agree to the Terms of Use and Privacy Policy. World Heritage Encyclopedia™ is a registered trademark of the World Public Library Association, a non-profit organization.
 



Copyright © World Library Foundation. All rights reserved. eBooks from World eBook Library are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.