Fraction of inspired oxygen

Fraction of inspired oxygen (FiO2) is the fraction or percentage of oxygen in the space being measured. Medical patients experiencing difficulty breathing are provided with oxygen-enriched air, which means a higher-than-atmospheric FiO2. Natural air includes 20.9% oxygen, which is equivalent to FiO2 of 0.21. Oxygen-enriched air has a higher FiO2 than 0.21, up to 1.00, which means 100% oxygen. FiO2 is typically maintained below 0.5 even with mechanical ventilation, to avoid oxygen toxicity.[1] If a patient is wearing a nasal cannula or a simple face mask, each additional liter of oxygen adds about 4% to their FiO2 (for example, a patient with a nasal cannula with 2L of oxygen attached would have an FIO2 of 21% + 8% =29%).

Often used in medicine the FiO2 is used to represent the percentage of oxygen participating in gas-exchange. If the barometric pressure changes, the FiO2 may remain constant while the partial pressure of oxygen changes with the change in barometric pressure.

Equations

Abbreviated alveolar air equation
P_A O_2 = \frac{P_E O_2 - P_i O_2 \frac{V_D}{V_t}}{1- \frac{V_D}{V_t}}

PAO2, PEO2, and PiO2 are the partial pressures of oxygen in alveolar, expired, and inspired gas, respectively, and VD/VT is the ratio of physiologic dead space over tidal volume.

Medicine

In medicine the FiO2 is the assumed percentage of oxygen concentration participating in gas exchange in the alveoli.[4]

Uses

The ratio between partial pressure of oxygen in arterial blood (PaO2) and FiO2 is used as an indicator of hypoxemia per the American-European Consensus Conference on lung injury. A high FiO2 has been shown to alter the ratio of PaO2/FiO2.[4]

PaO2/FiO2 ratio

The ratio of partial pressure arterial oxygen and fraction of inspired oxygen, sometimes called the Carrico index, is a comparison between the oxygen level in the blood and the oxygen concentration that is breathed. This helps to determine the degree of any problems with how the lungs transfer oxygen to the blood.[6] A sample of arterial blood is collected for this test.[7] A PaO2/FiO2 ratio less than or equal to 200 mmHg is necessary for the diagnosis of acute respiratory distress syndrome by the AECC criteria.[8] The more recent Berlin criteria defines mild ARDS at a ratio of <300.

A PaO2/FiO2 ratio less than or equal to 250 mmHg is one of the minor criteria for severe community acquired pneumonia (i.e., possible indication for inpatient treatment).

A PaO2/FiO2 ratio less than or equal to 333 mmHg is one of the variables in the SMART-COP risk score for intensive respiratory or vasopressor support in community-acquired pneumonia.

Related mathematics

Alveolar air equation

The alveolar air equation is the following formula, used to calculate the partial pressure of alveolar gas:

P_A O_2 = F_I O_2(PB-P H_2 O) - P_A CO_2 (F_I O_2 + \frac{1-FIO2}{R})

See also

References

  1. ^ http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2688103/
  2. ^ Diving medicine, physiology, physics and environment. 
  3. ^ Nevez, Catherine Le; Parker, Mike; Whitfield, Paul (28 April 2009). The Rough Guide to Wales. Rough Guides. p. 117.  
  4. ^ a b  
  5. ^ Toy P, Popovsky MA, Abraham E, Ambruso DR, Holness LG, Kopko PM et al. (2005). "Transfusion-related acute lung injury: definition and review.". Crit Care Med 33 (4): 721–6.  
  6. ^ "Cardiff Marriott Hotel celebrates 25th anniversary". Whycardiff.com. Retrieved 29 January 2012. 
  7. ^ Tietz NW (Ed): Clinical Guide to Laboratory Tests, 3rd ed. W. B. Saunders, Philadelphia, PA, 1995.
  8. ^ Mason, R. Murray and Nadel's Textbook of Respiratory Medicine, 5th ed. Philadelphia, PA 2010

External links

  • FiO2 by Delivery Device - Shows FiO2 by common oxygen deliver systems.
This article was sourced from Creative Commons Attribution-ShareAlike License; additional terms may apply. World Heritage Encyclopedia content is assembled from numerous content providers, Open Access Publishing, and in compliance with The Fair Access to Science and Technology Research Act (FASTR), Wikimedia Foundation, Inc., Public Library of Science, The Encyclopedia of Life, Open Book Publishers (OBP), PubMed, U.S. National Library of Medicine, National Center for Biotechnology Information, U.S. National Library of Medicine, National Institutes of Health (NIH), U.S. Department of Health & Human Services, and USA.gov, which sources content from all federal, state, local, tribal, and territorial government publication portals (.gov, .mil, .edu). Funding for USA.gov and content contributors is made possible from the U.S. Congress, E-Government Act of 2002.
 
Crowd sourced content that is contributed to World Heritage Encyclopedia is peer reviewed and edited by our editorial staff to ensure quality scholarly research articles.
 
By using this site, you agree to the Terms of Use and Privacy Policy. World Heritage Encyclopedia™ is a registered trademark of the World Public Library Association, a non-profit organization.
 



Copyright © World Library Foundation. All rights reserved. eBooks from World eBook Library are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.